Sign In | Join Free | My burrillandco.com
Home > Rooftop AC unit >

R410A T3 Working Condition Rooftop Air Conditioning Unit Floor Standing

    Buy cheap R410A T3 Working Condition Rooftop Air Conditioning Unit Floor Standing from wholesalers
     
    Buy cheap R410A T3 Working Condition Rooftop Air Conditioning Unit Floor Standing from wholesalers
    • Buy cheap R410A T3 Working Condition Rooftop Air Conditioning Unit Floor Standing from wholesalers
    • Buy cheap R410A T3 Working Condition Rooftop Air Conditioning Unit Floor Standing from wholesalers
    • Buy cheap R410A T3 Working Condition Rooftop Air Conditioning Unit Floor Standing from wholesalers

    R410A T3 Working Condition Rooftop Air Conditioning Unit Floor Standing

    Ask Lasest Price
    Brand Name : Shenglin
    Model Number : SRF Series
    Certification : CE
    Payment Terms : T/T, Western Union
    Supply Ability : 50~100 units/ month
    Delivery Time : 40~45days
    • Product Details
    • Company Profile

    R410A T3 Working Condition Rooftop Air Conditioning Unit Floor Standing

    T3 Working Condition Rooftop Ac Unit Suitable For The Middle East Country


    Description:

    1. Rooftop air conditioner generally have many functions such as refrigeration,heating,air supply,easy to use,low cost installation, low maintenance cost, widely used in air conditioning engineering project.


    2. Rooftop air conditioner,saving the cooling tower and cooling water pump cost for customers, is particularly suitable for water shortage area.It does not need special room for installation, and can be installed on the roof or building ground outside


    3. package unit heat pump is widely used in large space of centralized air treatment, such as convention and exhibition center,stadiums, theatres, shopping malls, supermarkets, waiting room, conference room, production workshop, library,etc.


    4. It is equipped with high performance compressor,low noise axial flow fan, high precision grades of electronic expansion valve,and advanced control system.


    Structure:
    1. Frame: channel steel sandblasting, then primer, then topcoat (sometimes primer and topcoat are also brushed with 2 coats), bolts SS304.
    2. Epoxy aluminum fin heat exchangers.
    3. Can be used under T3 working conditions and can withstand an environment of up to 55°c (for 2 reasons):
    A. Parallel compressors (can be stopped when the ambient temperature is high, and one compressor can be stopped when the ambient temperature is the highest.

    B. All fans are EC frequency conversion, stepless speed regulation (continuous speed regulation).
    Technical paramater:
    ModelSRF12ZASRF 15ZASRF18ZASRF24ZASRF30ZASRF35ZA
    SF12ZASF15ZASF18ZASF24ZASF30ZASF35ZA
    Nominal cooling capacitykW1215.217.52430.335.6
    Nominal heating capacitykW13.216.618.426.533.337.7
    Energy regulation%0,100%0,50,100%
    Power supply380V / 3Ph / 50HZA
    Cooling input capacitykW4.15.35.58.811.312.3
    Heating input capacitykW3.84.85.18.210.411.3
    Start currentA486263637476
    Cooling running currentA7.49.710.216.121.223.3
    Heating running currentA6.99.29.715.120.122.2
    Throttling methodThermal expansion valve
    Cooling system111122
    RefrigerantR410A
    CompressorTypeHermetic scroll compressor
    Qty111122
    Condensation side
    CondenserTypeCopper tube and aluminum fin
    Qty111111
    Drive typeDirect drive
    Motor powerkW0.250.370.370.550.750.75
    Air volumem3 /h46007800780090001260012600
    Evaporation side
    EvaporatorTypeCopper tube and aluminum fin
    Qty111111
    Motor powerkW0.320.370.451.11.52.2
    Air volumem3 /h210026003400410052006300
    Drive typeDirect drivePulley
    Static pressure(Pa)100100100200200250
    FilterAluminum filter G3
    Noise dB(A)676768717272
    Refrigerant filling volume(kg)3.13.14.32x3.12x3.12x4.3
    Overall dimensionsLength(mm)mm141014101410197819781978
    Width(mm)mm110011001100117511751175
    Height(mm)mm109510951095109510951095
    Weightkg240260290420480500
    Note: 1. Nominal cooling capacity is under nominal air volume, indoor DB/WB temperature is 27℃/19℃ and outdoor DB/WB temperature is 35℃/24℃ condition;
    2. Nominal heating capacity is under nominal air volume, indoor DB/WB temperature is 20℃/15℃ and outdoor DB/WB temperature is 7℃/6℃ condition;

    Preferred Usage Areas
    Commercial Building Air Conditioning
    Hotel Air Conditioning
    Airport Air Conditioning


    Some overseas project:


    Pre-Sales Service:
    * Inquiry and consulting support.
    * Sample testing.
    * View our Factory.


    After-Sales Service:
    * Training how to instal the machine, training how to use the machine.
    * Engineers available to service machinery overseas.

    Quality R410A T3 Working Condition Rooftop Air Conditioning Unit Floor Standing for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shanghai Shenglin M&E Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)