Sign In | Join Free | My burrillandco.com
Home > Bitcoin Cooling System >

Two Phase Liquid Cooling Immersion Cryptocurrency Cooler

    Buy cheap Two Phase Liquid Cooling Immersion Cryptocurrency Cooler from wholesalers
     
    Buy cheap Two Phase Liquid Cooling Immersion Cryptocurrency Cooler from wholesalers
    • Buy cheap Two Phase Liquid Cooling Immersion Cryptocurrency Cooler from wholesalers
    • Buy cheap Two Phase Liquid Cooling Immersion Cryptocurrency Cooler from wholesalers
    • Buy cheap Two Phase Liquid Cooling Immersion Cryptocurrency Cooler from wholesalers
    • Buy cheap Two Phase Liquid Cooling Immersion Cryptocurrency Cooler from wholesalers
    • Buy cheap Two Phase Liquid Cooling Immersion Cryptocurrency Cooler from wholesalers
    • Buy cheap Two Phase Liquid Cooling Immersion Cryptocurrency Cooler from wholesalers
    • Buy cheap Two Phase Liquid Cooling Immersion Cryptocurrency Cooler from wholesalers

    Two Phase Liquid Cooling Immersion Cryptocurrency Cooler

    Ask Lasest Price
    Brand Name : Shenglin
    Model Number : SHSL-D1 Series
    Certification : CE
    Price : 660~30000 USD per unit
    Payment Terms : T/T, Western Union
    Supply Ability : 100 units per month
    Delivery Time : 30~35 days
    • Product Details
    • Company Profile

    Two Phase Liquid Cooling Immersion Cryptocurrency Cooler

    Two-phase Liquid Cooling Liquid Immersion Cooling Systems For Cryptocurrency Mining Farms


    What's Immersion Cooling?

    Also known as liquid submersion cooling. It is the practice of submerging computer components (or full servers) in a thermally, but not electrically, conductive liquid (dielectric coolant) allowing higher heat transfer performance than air and many other benefits.

    Why many large data centers have already moved or are considering the move to immersion cooling?


    1. Up to 25% increase in power efficiency
    2. Up to 80% cost reduction
    3. Up to 60% hashrate increase
    4. 50%+ equipment lifespan.

    Introduction of Two-phase Liquid Cooling:

    The cooling liquid undergoes a phase change in the process of circulating heat dissipation. The cooling liquid takes away the heat from the server and then undergoes a phase change gasification. The gaseous cooling liquid is condensed by the condenser and becomes liquid again and returns to the liquid cooling tank; the cooling liquid can use 3M electronics The boiling point of the coolant FC-72 and FC-72 is above 50℃.
    In this case, the temperature of the water in the condensing coil does not need to be too low. The use of a dry cooler can meet the heat exchange requirements and take away the heat.
    The two-phase liquid cooling has a high heat transfer efficiency due to the phase change of the electronic cooling liquid.
    The disadvantage is that during this phase change, the electronic fluorinated liquid will escape during the vaporization process, so there is a certain degree of tightness of the container. However, it should not be too sealed to prevent the cooling system from being interrupted and the cylinder explosion event, so certain safety facilities need to be set up.

    Technical parameter

    Dry cooler D1 series parameter (fin space 2.1mm)

    Type

    D1-005-

    1x350

    D1-006-

    1x350

    D1-007-

    1x350

    D1-009-

    1x450

    D1-011-

    1x450

    D1-013-

    1x450

    D1-014-

    1x500

    D1-017-

    1x500

    D1-020-

    1x500

    CapacityWater35℃ outdoor temp.Inlet45℃KW4.895.96.839.3910.9913.3314.3217.0119.8
    outlet40℃Y
    20% GlycolInlet45℃4.725.696.698.910.6113.0513.9116.1119.29
    outlet40℃Y
    MediumWater flowM3/h0.851.031.21.631.912.32.533.5
    Pressure dropkPa363158254080506040
    Air flowM3/h282827122492619958275225846981687601
    Y
    Fan motorPhase111333333
    W140140140540540540830830830
    Y
    A0.60.60.61.11.11.11.451.451.45
    Y
    FanNo X φ1x1x3501x1x3501x1x3501x1x4501x1x4501x1x4501x1x5001x1x5001x1x500
    Sound pressure leveldB(A)313131434343494949
    Y10m
    DimensionLmm870870870102010201020122012201220
    Wmm525525525625625625825825825
    Hmm797797797820820820870870870
    Amm690690690840840840104010401040
    Bmm------------------
    Cmm------------------
    Dmm490490490490490490490490490
    Inlet φmm3/4”3/4”3/4”1”1”1”1-1/4”1-1/4”1-1/4”
    Inlet φmm3/4”3/4”3/4”1”1”1”1-1/4”1-1/4”1-1/4”
    Product weight(empty)kg384248556067758291

    Note: Standard SHSL-D1 dry cooler is vertical air discharge, for horizontal air discharge please add “H” in nomenclature, for excmple:SHSL-D1-005H-1X350


    Some data center cooling reference:


    For data center cooling:

    Country: Mongolia

    Application: match with precision air conditioner

    Cooling capacity: 17.6kW

    Cooling medium: 34% ethylene glycol

    Supply power: 400V/3P/50Hz

    Fan brand: Ziehl-Abegg

    Country: Russia

    Application:data center cooling

    Cooling capacity: 763kW

    Cooling medium: water

    Supply power: 380V/3P/50Hz

    Fan brand: Ziehl-Abegg


    Two Phase Liquid Cooling Immersion Cryptocurrency CoolerTwo Phase Liquid Cooling Immersion Cryptocurrency Cooler

    Two Phase Liquid Cooling Immersion Cryptocurrency Cooler

    Two Phase Liquid Cooling Immersion Cryptocurrency Cooler


    The immersion cooling system diagram by dry cooler/dry cooling tower:

    Quality Two Phase Liquid Cooling Immersion Cryptocurrency Cooler for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shanghai Shenglin M&E Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)