Dielectric Fluids V Type Datacentre Immersion Cooling System

    Buy cheap Dielectric Fluids V Type Datacentre Immersion Cooling System from wholesalers
     
    Buy cheap Dielectric Fluids V Type Datacentre Immersion Cooling System from wholesalers
    • Buy cheap Dielectric Fluids V Type Datacentre Immersion Cooling System from wholesalers
    • Buy cheap Dielectric Fluids V Type Datacentre Immersion Cooling System from wholesalers
    • Buy cheap Dielectric Fluids V Type Datacentre Immersion Cooling System from wholesalers
    • Buy cheap Dielectric Fluids V Type Datacentre Immersion Cooling System from wholesalers
    • Buy cheap Dielectric Fluids V Type Datacentre Immersion Cooling System from wholesalers
    • Buy cheap Dielectric Fluids V Type Datacentre Immersion Cooling System from wholesalers
    • Buy cheap Dielectric Fluids V Type Datacentre Immersion Cooling System from wholesalers
    • Buy cheap Dielectric Fluids V Type Datacentre Immersion Cooling System from wholesalers
    • Buy cheap Dielectric Fluids V Type Datacentre Immersion Cooling System from wholesalers
    • Buy cheap Dielectric Fluids V Type Datacentre Immersion Cooling System from wholesalers

    Dielectric Fluids V Type Datacentre Immersion Cooling System

    Ask Lasest Price
    Brand Name : Shenglin
    Model Number : H*FD Series Double rows fans
    Certification : CE and RoHs
    Price : 6000~49005 USD per unit
    Payment Terms : T/T, Western Union
    Supply Ability : 100 units per month
    Delivery Time : 30~35days
    • Product Details
    • Company Profile

    Dielectric Fluids V Type Datacentre Immersion Cooling System

    Dielectric Fluids V Type Dry Cooler For Datacentre Immersion Cooling System


    Why immerse?


    1. Silent Operations - Whether it’s single or two-phase immersion cooling, liquid cooling keeps your hardware submerged in a dielectric fluid of some type. More importantly, that will eliminates the noisy fans, which should be running throughout day and night in condition of air-based cooling and consume roughly 25-30% in additional power required to keep compute equipment on-line.
    2. Reduced PUE - Power usage effectiveness (PUE) is the ratio of a data center’s total facility energy to its total IT equipment (ITE) energy.Legacy or underside air-cooled techniques can struggle to maintain in the 1.8 to 2.4 range. Modern, purpose-built data centers have achieved significant PUE reductions using air-cooled chillers with closed-loop systems, often hitting a PUE of 1.3-1.5.With immersion cooling, PUE consistently stays under 1.3, drastically reducing a facility’s energy load.
    3. Cost Savings - Cooling accounts for a large part of operating expenses. A facility that houses thousands of servers is also expected to run 24/7, 365 days a year. In traditional air cooling, a large number of fans, HVAC and CRAC systems contribute a lot to the electricity bill. However, when servers are submerged in thermally conductive cooling solutions, electricity usage is reduced by more than 95%, which no one can refuse.

    Introduction of two-phase liquid cooling:


    The cooling liquid undergoes a phase change in the process of circulating heat dissipation. The cooling liquid takes away the heat from the server and then undergoes a phase change gasification. The gaseous cooling liquid is condensed by the condenser and becomes liquid again and returns to the liquid cooling tank; the cooling liquid can use 3M electronics The boiling point of the coolant FC-72 and FC-72 is above 50℃. In this case, the temperature of the water in the condensing coil does not need to be too low. The use of a dry cooler can meet the heat exchange requirements and take away the heat. The two-phase liquid cooling has a high heat transfer efficiency due to the phase change of the electronic cooling liquid. The disadvantage is that during this phase change, the electronic fluorinated liquid will escape during the vaporization process, so there is a certain degree of tightness of the container. However, it should not be too sealed to prevent the cooling system from being interrupted and the cylinder explosion event, so certain safety facilities need to be set up.


    Features

    • Our range of Dry Air Coolers and Radiators are designed for commercial and industrial fluid cooling applications.
    • We offer a wide range of options to provide the most cost-effective solution for your cooling requirement.
    • Standard arrangements include flat-bed vertical or horizontal airflow with V configurations to offer the smallest footprint.
    • Whether your application is cooling water / glycol for water cooled chillers, injection moulding machines, furnace equipment, CHP Engine Cooling or any other process. One or more of our units can be selected to provide the most cost-effective solution to suit your space and noise requirement.
    • Energy saving free cooling is possible for much of the year for many applications.

    Why choose us:

    1. We can help buyers design specific products or produce products according to buyers' design
    2. We can print logo according to buyers' requirement
    3. We has exported to many countries,such as Singapore, Philippines, Vietnam, Argentina, Peru, Mongolia, Hong Kong, UAE,Russia, Poland etc.
    4. Design term: We have professional design team.
    5. Professional factory: We are manufacturer, specializing in manufacturing heat exchangers for over 16years, competitive price with good quality.
    6. Rapid response to your needs: We will reply within 24 hours after receiving you letter. If you have urgent thing, welcome to call us.
    7. The Most Efficient Service, Best Quality and Excellent Reputation.

    Technical Paraments


    Flat series — Double rows fans

    H*FD*91Fan Dim
    mm
    *H*FD491H*FD691H*FD89H*FD1091H*FD1291H*FD1491H*FD1691H*FD1891
    Rated Capacities (kW) Heat Exchange Surface (㎡)
    Fluid Coolers910D237kW-1632kW 454㎡-4903㎡ (Water/Ta25℃/Tin40℃/Tout35℃)
    Freon Condensers910F285kW-1632kW 454㎡-4903㎡ (R404A/Ta35℃/Tk50℃)
    Ammonia Condensers910A151kW-1709kW 263㎡-5696㎡ (NH3/Ta35℃/Tk50℃)
    Gas Coolers910G156kW-1929kW 358㎡-3859㎡ ( CO2/Tair32℃/Tin113℃/P94Bar/Tout34℃)
    Oil Coolers910O174kW-2212kW 454㎡-4903㎡ (OIL ISO VG 46/Ta35℃/Tin85℃/Tout60℃)
    Fan Model910ECW3G910KU2503 (2.55kW) or FN091-ZIQ.GL.V5P1 (3.2kW)
    910ACW6D910GB0101 (2.02kW) or FN091-SDS.6N.V7P2 (1.85kW)
    No of Fans4681012141618
    Overall Dimensions910Lenth-134804980648079809480109801248013980
    Lenth-2408058807680948011280130801488016680
    Width2265
    Height1740 (Including 800Leg)



    Options

    Coil design refrigerant: water, oil, glycolMultiple circuits
    Sub-cooling circuitsStainless steel or aluminum casing
    Coated aluminum or copper finsExplosion proof motor
    Customized fin spacing

    Reference:

    For data center coolingCountry: Mongolia
    Application: match with precision air conditioner
    Cooling capacity: 17.6kW
    Cooling medium: 34% ethylene glycol
    Supply power: 400V/3P/50Hz
    Fan brand: Ziehl-Abegg
    Country: Russia
    Application:data center cooling
    Cooling capacity: 763kW
    Cooling medium: water
    Supply power: 380V/3P/50Hz
    Fan brand: Ziehl-Abegg
    Dielectric Fluids V Type Datacentre Immersion Cooling SystemDielectric Fluids V Type Datacentre Immersion Cooling System
    For power plantCountry: Hongkong
    Application: power plant
    Cooling capacity: 363kW
    Cooling medium: water
    Supply power: 415V/3P/50Hz
    Fan brand: Chinese brand
    Country: Russia
    Application: power plant.
    Cooling capacity: 180kW
    Cooling medium: water
    Supply power: 380V/3P/50Hz
    Fan brand: Chinese brand
    Dielectric Fluids V Type Datacentre Immersion Cooling SystemDielectric Fluids V Type Datacentre Immersion Cooling System
    Quality Dielectric Fluids V Type Datacentre Immersion Cooling System for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shanghai Shenglin M&E Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)