Sign In | Join Free | My burrillandco.com
Home > Industrial Dry Cooler >

V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System

    Buy cheap V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System from wholesalers
     
    Buy cheap V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System from wholesalers
    • Buy cheap V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System from wholesalers
    • Buy cheap V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System from wholesalers
    • Buy cheap V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System from wholesalers
    • Buy cheap V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System from wholesalers
    • Buy cheap V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System from wholesalers

    V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System

    Ask Lasest Price
    Brand Name : Shenglin
    Model Number : D1 Series
    Certification : CE certification
    Price : 505~31005 USD/Unit
    Payment Terms : T/T, Western Union
    Supply Ability : 50~100 units per month
    Delivery Time : 35~40days
    • Product Details
    • Company Profile

    V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System

    V-Type Copper Tube Dry Type Air Cooler For Immersion Cooling System


    What is closed-loop dry cooling system?


    The strength of a closed-loop dry cooling system is that the unit is very simple and relatively easy to install. The energy requirements are relatively low and it is easily controlled. Maintenance is normally low requiring only periodic inspection, lubrication, and testing of the fluid.


    The weakness of a closed-loop dry cooling system is that it is dependent on the atmospheric dry bulb. For example, if your location’s design dry bulb is 100 F in the summer and your equipment requires 90 F coolant; at best the system can only supply around 105 to 110 F coolant to the load. In this case you would need supplemental cooling to get the coolant temperatures down to 90 F.


    The closed-loop dry cooling system also requires free clear air to work efficiently. This means that the fluid cooler must be placed in a location that is not affected by the prevailing winds, not too close to a building that will allow the warm exhaust air from the fluid cooler to be recirculated back to the fluid cooler, and finally not in a location that has heavy concentrations of dust, dirt, leaves, seeds, etc.


    Many times the best location for the fluid cooler is on the roof. Since the fluid cooler is located outside the coolant must also have a concentration of some type of glycol to prevent freezing if your location has a design dry bulb in the winter that dips below freezing. If the location is very cold, the concentration of glycol may need to be significant to prevent freezing. Glycol concentrations as they increase begin to reduce the rate of heat transfer. For example, if you need 50% ethylene glycol concentration with water the heat exchanger equipment and the flow/pressure of the coolant will need to increase to adjust for the glycol concentration. Larger fluid coolers and pumps will increase the cost of the system over those with lesser concentrations of Glycol/water. This cannot be prevented in colder climates.


    Dry fluid cooler features:

    Air discharge direction
    Performance ranges

    Cooling capacity: from 5 to 649 kw

    Air volume: from 2828 to 263503 m3/h

    Sound pressure level: from 31 to 69 dB A(10m)

    Dry coolers:customized on demand

    High efficiency heat exchanger

    Capacity designs for maximizing the heat transfer relative to the energy consumption of the fan.

    Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition).

    Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany

    Fan

    Only choose low specific energy consumption fans.

    Fan nozzle designs for maximum air flow and air throw.

    Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting.

    Motor: protection class IP 54 and insulation class F.

    Voltage:400V/3N/50Hz

    Air separator for each fan.

    TestingHeat exchangers are supplied clean and tested at a pressure of 30 bars
    Options

    Coil design refrigerant: water, oil, glycol.

    Multiple circuits.

    Sub-cooling circuits.

    Stainless steel or aluminum casing.

    Coated aluminum or copper fins.

    Explosion ploof motor.

    Customized fin spacing.



    Dry fluid cooler technical parameter

    Dry cooler D1 series parameter(fin space 2.1mm)

    Type

    D1-166-

    4x630

    D1-211-

    6x630

    D1-247-

    6x630

    D1-286-

    8x630

    D1-334-

    8x630

    D1-360-

    10x630

    D1-415-

    10x630

    D1-502-

    12x630

    D1-565-

    14x630

    D1-649-

    16x630

    CapacityWater35℃ outdoor temp.Inlet45℃,KW165.92211.36247.3286.15334.49359.72415.31502.25565.18649.48
    outlet40℃Y134.59176.00200.45238.3270.889298.57335.225405.20459.3527.59
    20% GlycolInlet45℃161.32205.08240.46280.05327.72351.3406.48493.40554.21638.44
    outlet40℃Y130.96170.87195.07233.18265.64291.81328.48398.45450.87519.13
    MediumWater flowM3/h29.003743505863728898113
    Pressure dropkPa50704797959270979695
    Air flowM3/h67455109723101185146293134908179502164442197326230584263503
    Y512658366176900111544102528136437124680149612174710199665
    Fan motorPhase3333333333
    W1100165001650022000220002750027500330003850044000
    Y700105001050014000140001750017500210002450028000
    A20.430.630.640.840.851.0051.0061.2071.4081.60
    Y12.0018.0018.0024.0024.0030.0030.0036.0042.0048.00
    FanNo X φ

    2X2

    X630

    2x3

    x630

    2x3

    x630

    2x4

    x630

    2x4

    x630

    2x5

    x630

    2x5

    x630

    2x6

    x630

    2x7

    x630

    2x8

    x630

    Sound pressure leveldB(A)64666667676868686969
    Y10m57595960606161616262
    DimensionLmm29304230423055305530683068308130943010730
    Wmm2100210021002100210021002100210021002100
    Hmm1070107010701070107011201120112011201120
    Amm--------------------
    Bmm1340134013401340134013401340134013401340
    Cmm1300130013001300130013001300130013001300
    Dmm640640640640640640640640640640
    Inlet φmm3”3”3”DN100DN100DN100DN125DN125

    2X

    DN125

    2X

    DN125

    Inlet φmm3”3”3”DN100DN100DN100DN125DN125

    2X

    DN125

    2X

    DN125

    Product weight(empty)kg6586897601105127013201420158418482112

    Application:

    Industrial field: process engineering, heat / power plant, power generation, chemical industry, air conditioning chiller, heat transformer, sloar system, smelting, etc.. It is suitable for all equipment which needs heat dissipation and is installed in the open air.


    How to design a dry cooler?


    Tell Shenglin the datas as following:
    A. Required electrolyte inlet temperature?
    B. Required electrolyte​ outlet temperature?
    C. Electrolyte​ flow?
    D. Ambient temperature?
    E. Supply power(voltage-Hz-phase)
    G. Any other requirements ?


    Reference:

    For solar industryCountry: China
    Application :cooling of solar heating system when it is overheated
    Cooling capacity: 463, 933 and 1475kW
    Cooling medium: 50% propylene glycol water
    Supply power: 380V/3P/50Hz
    Fan brand: Ziehl-Abegg
    Altitude:4200m
    Country: UAE
    Application: solar thermal system
    Cooling capacity: 21kw
    Cooling medium: water
    Supply power: 230V/1P/50Hz
    Fan brand: Chinese brand
    Country: Korea
    Application: solar system overheated
    Cooling capacity: 32kW
    Cooling medium: 30% ethylene glycol water
    Supply power: 230V/1P/60Hz
    Fan brand: Chinese brand
    V Type Copper Tube Dry Type Air Cooler For Immersion Cooling SystemV Type Copper Tube Dry Type Air Cooler For Immersion Cooling SystemV Type Copper Tube Dry Type Air Cooler For Immersion Cooling System
    For plastic industryCountry: Algeria
    Application: cooling water from injection molding machine
    Cooling capacity: 694kW
    Cooling medium: water
    Supply power: 400V/3P/50Hz
    Fan brand: Ziehl-Abegg
    Country: Armenia
    Application: for plastic caps of beverages factory
    Cooling capacity:70kW
    Cooling medium: 34% ethylene glycol
    Supply power: 380V/3P/50Hz
    Fan brand: Chinese brand
    Country: Russia
    Application: bathtub factory
    Inlet/outlet air temperature:40℃/66℃
    Inlet/outlet water temperature:85℃/50℃
    Air volume:7986m3/h
    Cooling medium:water
    Supply power: 380V/3P/50Hz
    Fan brand: Chinese brand
    V Type Copper Tube Dry Type Air Cooler For Immersion Cooling SystemV Type Copper Tube Dry Type Air Cooler For Immersion Cooling SystemV Type Copper Tube Dry Type Air Cooler For Immersion Cooling System
    Instead of cooling towerCountry: Argentina
    Application: for equipment cooling, to match chiller.
    Cooling capacity: 245kW
    Cooling medium: water
    Supply power:380V/3P/50Hz
    Fan brand: Chinese brand


    Country: Peru
    Application: instead of cooling tower, to match chiller.
    Cooling capacity: 360kW
    Cooling medium: water
    Supply power:440V/3P/60Hz
    Fan brand: Chinese brand
    With wet curtain, with water pump and water tank
    Country: Mauritius
    Application: supermarket and will match chiller use.
    Heat transfer capacity: 502kW
    Cooling medium: water
    Inlet air temp.: 32℃
    Inlet medium temp.: 42℃
    Outlet medium temp.: 37℃
    Medium volume: 88m3/h
    Material: copper tube aluminum fin and galvanized steel frame, RAL9010 powder coating.
    Supply power: 380V/3P/50Hz
    Fan brand: Chinese brand, air volume: 20228m3/h
    V Type Copper Tube Dry Type Air Cooler For Immersion Cooling SystemV Type Copper Tube Dry Type Air Cooler For Immersion Cooling SystemV Type Copper Tube Dry Type Air Cooler For Immersion Cooling System
    For data center coolingCountry: Mongolia
    Application: match with precision air conditioner
    Cooling capacity: 17.6kW
    Cooling medium: 34% ethylene glycol
    Supply power: 400V/3P/50Hz
    Fan brand: Ziehl-Abegg
    Country: Russia
    Application:data center cooling
    Cooling capacity: 763kW
    Cooling medium: water
    Supply power: 380V/3P/50Hz
    Fan brand: Ziehl-Abegg
    V Type Copper Tube Dry Type Air Cooler For Immersion Cooling SystemV Type Copper Tube Dry Type Air Cooler For Immersion Cooling System
    Factory coolingCountry: Russia
    Application: ore yard cooling
    Cooling capacity: 493kW
    Cooling medium: 20% ethylene glycol
    Supply power: 400V/3P/50Hz
    Fan brand: Ziehl-Abegg
    Country: China
    Application: plant cooling
    Cooling capacity: 52kW
    Cooling medium: 30% ethylene glycol
    Supply power: 380V/3P/50Hz
    Fan brand: Chinese brand
    V Type Copper Tube Dry Type Air Cooler For Immersion Cooling SystemV Type Copper Tube Dry Type Air Cooler For Immersion Cooling System
    For power plantCountry: Hongkong
    Application: power plant
    Cooling capacity: 363kW
    Cooling medium: water
    Supply power: 415V/3P/50Hz
    Fan brand: Chinese brand
    Country: Russia
    Application: power plant.
    Cooling capacity: 180kW
    Cooling medium: water
    Supply power: 380V/3P/50Hz
    Fan brand: Chinese brand
    V Type Copper Tube Dry Type Air Cooler For Immersion Cooling SystemV Type Copper Tube Dry Type Air Cooler For Immersion Cooling System
    Other applicationCountry: Singapore
    Application: match with fruit and vegerable freezer
    Cooling capacity: 14.6kw, 17kw and 29.37kw
    Cooling medium: 20% ethylene glycol
    Supply power: 230V/1P/50Hz
    Fan brand: Ziehl-Abegg
    Country: Singapore
    Application: wastewater treatment factory, cooling water
    Cooling capacity: 429kW
    Cooling medium: water
    Supply power: 400V/3P/50Hz
    Fan brand: Ziehl-Abegg
    Country: Russia
    Application: industrial cooling
    Cooling capacity: 153kW
    Cooling medium: 20% glycol
    Supply power: 380V/3P/50Hz
    Fan brand: Ziehl-Abegg
    V Type Copper Tube Dry Type Air Cooler For Immersion Cooling SystemV Type Copper Tube Dry Type Air Cooler For Immersion Cooling SystemV Type Copper Tube Dry Type Air Cooler For Immersion Cooling System
    Quality V Type Copper Tube Dry Type Air Cooler For Immersion Cooling System for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shanghai Shenglin M&E Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)