    PCR Laboratory Close Control AHU Clean Room Air Conditioner

    Ask Lasest Price
    Brand Name : Shenglin
    Model Number : Non standard
    Certification : CE
    Price : 5000~10015USD/unit
    Payment Terms : T/T, Western Union
    Supply Ability : 100 Units Per Month
    Delivery Time : 40~45 days
    • Product Details
    • Company Profile

    PCR Laboratory Close Control AHU Clean Room Air Conditioner

    Close Control Clean Room Air Conditioning System For PCR Laboratory

    Feature: integral design, simple and convenient installation and operation, inverter compressor, dual EC fan, PLC high precision constant temperature and humidity control. Non-standard design.

    Standard DX AHU Technical Paramater:
    Unit characteristicsModel: SL-ZKW-( ) DX203040506580100
    Cooling capacity 1*kw10.115.320.325.532.338.652.0
    Heating capacity 2*kw10.315.720.826.133.539.553.2
    Air volume 3*m3/h20003000400050006500800010000
    Static air pressure 3*Pa200250300300400400500
    power3N-380V-50Hz
    Indoor unitSupply air fan 3*TypeEfficient centrifugal fan
    kw0.550.751.52.23.03.05.5
    Chilled water coil 4*(option)TypeEfficient copper tube and aluminum fin
    Flow m3/h1.72.63.54.45.66.68.9
    Section length(mm)300300300300300300300
    Heater 5*TypeStainless steel tube electric heating/ steam heating coil/hot water heating coil
    kw691218242430
    Section length(mm)300300300300400400400
    Humidifier 5*TypeElectrode type/steam/electrothermic type/wet film
    kg/h345881212
    Section length(mm)400400400400400400400
    Filter 6*TypePrimary filter G4(medium effect F8/ Nanocrystalline carbon filter
    NoisedB(A)60606162636365
    Overall dimension 7*Length(mm)1800200020002100210022002400
    Width(mm)730103010301030114013401340
    Height(mm)78878811151115111511151420
    Weightkg40180320400580660800
    Outdoor unitModel: SL-WL10152025354055
    Compressor ATypeHermetic scroll type (Fixed frequency system)
    Qty1111122
    Input power Akw3.44.86.38.09.812.716.1
    Compressor BTypeHermetic scroll type (Inverter system)
    Qty1111122
    Input power Bkw3.34.66.27.79.712.615.6
    Refrigerant 8*TypeR22/R407C/R410A
    ModeExternal balance type thermal expansion valve/electronic expansion valve
    Noise 9*dB(A)63636464656567
    Overall dimensionLength(mm)85085098098098018801880
    Width(mm)85085098098098018801880
    Height(mm)1080108010801080123410801080
    Weightkg130135150180220280320
    Connection pipe size 10*Liquid pipe(mm)12.7(9.52)12.7(9.52)12.7(12.7)15.88(12.7)15.88(12.7)15.88*2(12.7*2)15.88*2(12.7*2)
    Steam pipe(mm)15.88(12.7)19.05(15.88)19.05(15.88)28.6(22.23)28.6(22.23)22.23*2(19.05*228.6*2(22.23*2)

    1. Cooling condition: indoor dry bulb/wet bulb 27/19℃; outdoor dry bulb/wet bulb 35/24℃

    2. Heating condition: indoor dry bulb/wet bulb 20/-℃; outdoor dry bulb/wet bulb 7/6℃

    3. Air volume, pressure, power in the table is standard parameters. It can be separately designed according to customer`s requirements

    4. Chilled water coil as optional parts, according to the customer site requirements configured to double cold source unit.

    5. Heater, humidifier, heat recovery device as optional parts, according to the customer requirements configured to the other forms.

    6. Unit standard uses G4 level filters, according to the customer requirements configured to the other forms.

    7. Unit length does not include the function section .Such as heating section, humidification section. Specific details please consult us.

    8. Air cooled split type air conditioning unit without refrigerant leaving the factory, refrigerant models need to be indicated in the order.

    9. Noise data is measured 2m in front of the unit, 1.2m high, when cooling under the standard air volume.

    11.Inside of bracket is R410A refrigerant type connection pipe diameter, the connection copper pipe between the indoor and outdoor unit should within 35 meters.


    Our laboratory:

    Packing way:



    Reference:

    Quality PCR Laboratory Close Control AHU Clean Room Air Conditioner for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shanghai Shenglin M&E Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)